Installation
AC-F/G4x Family Installation and Programming Manual 15
6. Once wired, replace the controller back onto its back plate and
secure using the tamper-proof screw and special tool, supplied
with the hardware.
3.2 Wiring Instructions
The controllers are provided with a one-meter, pre-wired, 10-
conductor 18-AWG cable.
To wire the controller:
1. Cut and strip the conductors to the necessary length.
2. Splice the controller pigtail wires to the corresponding ancillary
devices and insulate each connection, including unused wires.
3. Refer to Table 1 and to the wiring diagrams, depending on the
desired application:
Wiring the Lock Strike Relay and REX (Figure 4)
Wiring for Auxiliary Input and Output (Figure 5)
Wiring for the BL-D40 External Sounder (Figure 6)
Table 1: Wiring Color Guide
Color Description
Red V input
Black Ground
Green REX/BL
White In / Monitor
Purple Lock: Com
Gray Lock: N.O.
Brown Lock: N.C.
Blue Aux: Com
Yellow Aux: N.O.
Orange Aux: N.C.