Rosslare AC-225? AC-225IP? AC-225U User's Guide

Browse online or download User's Guide for Security access control systems Rosslare AC-225? AC-225IP? AC-225U. Rosslare AC-225? AC-225IP? AC-225U User guide User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - AC-225

AC-225 Advanced Scalable Networked Access Controller Hardware Installation and User Guide July 2007

Page 2

Technical Specifications AC-225 Hardware Installation and User Guide Page 9 Power Supply Specifications Input Voltage 16V AC / 2.5A From Transforme

Page 3

AC-225 Panel Set-Up 3. AC-225 Panel Set-Up Every AC-225 panel controls one or two doors. The panels connect together in a network and are controlled

Page 4 - 1. Introduction

AC-225 Panel Set-Up 3.1 Inputs Wiring – Non-Supervised Inputs Figure 3: Inputs Wiring – Non-supervised Inputs 3.2 Inputs Wiring – Supervised Input

Page 5 - Introduction

AC-225 Panel Set-Up 3.3 Outputs Wiring The following diagram illustrates wiring for two main types of 12VDC electrical release mechanisms. Other ele

Page 6 - 1.2 VeriTrax AS-225

AC-225 Panel Set-Up AC-225 Hardware Installation and User Guide Page 13 3.4 Power Supply The following diagram illustrates wiring between the PS-14

Page 7 - Fingerprint Recognition

AC-225 Panel Set-Up Figure 6: Wiring Between PS-14 and AC-225 AC-225 Hardware Installation and User Guide Page 14

Page 8 - 2. Technical Specifications

AC-225 Panel Set-Up 3.5 Reader Proximity & keypad readers are supplied with a limited cable. The color of the cable cover represents the cable’s

Page 9 - Transformer

Input and Output Requirements AC-225 Hardware Installation and User Guide Page 16 4. Input and Output Requirements This chapter describes the AC-22

Page 10 - Power LEDs

Input and Output Requirements Normally Open Input Connection: Normally Open Input has 2 states: • Switch Open - Normal State: Loop resistance = Infi

Page 11 - 3. AC-225 Panel Set-Up

Input and Output Requirements Normally Closed Input Connection: Normally Closed Input has two states: • Switch Closed - Normal State: Loop resistance

Page 13 - 3.3 Outputs Wiring

Input and Output Requirements Normally Open Supervised Single Resistor Input Connection Connect an 8.2K resistor in parallel to the input switch conta

Page 14 - 3.4 Power Supply

Input and Output Requirements Normally Open Supervised Double Resistor Input Connection Connect a 2.2K resistor in series to the input switch contacts

Page 15 - AC-225 Panel Set-Up

Input and Output Requirements Normally Closed Supervised Single Resistor Input Connection Connect a 2.2K resistor in series to the input switch contac

Page 16 - 3.5 Reader

Input and Output Requirements • Open circuit (Infinite loop resistance) or short circuit (0 resistance) across input terminals - Trouble State. Figu

Page 17 - 4.1 Input Types

Input and Output Requirements Door Monitor Input The Door Monitor Input typically connects to a Normally Closed door sensing micro-switch for door sta

Page 18

Input and Output Requirements General Purpose Inputs These are free inputs that can be used for various functions. The following should be defined: S

Page 19

Input and Output Requirements Note: The user can select either "Normally Open" or "Normally Closed" output contacts. The followi

Page 20

Input and Output Requirements AC-225 Hardware Installation and User Guide Page 26 Single door controller: Door 1 – Reader 1 IN/OUT Door 1 – Reader

Page 21

AC-225 Hardware Settings AC-225 Hardware Installation and User Guide Page 27 5. AC-225 Hardware Settings Each AC-225 panel controls an entrance. The

Page 22

AC-225 Hardware Settings 5.1 DIP Switch Configuration The access control panel DIP switch controls a number of operating parameters including the dev

Page 23 - 4.2 Inputs Description

Table of Contents AC-225 Hardware Installation and User Guide Page ii Table of Contents 1. Introduction...

Page 24 - Door Monitor Input

AC-225 Hardware Settings 1 2 3 4 5 6 7 8 Figure 15: DIP Switch with Baud Rate Setting The following lists switch 1 and 2 status and baud r

Page 25 - 4.3 Outputs

AC-225 Hardware Settings Single Door Controller This access type has two readers, IN and OUT, as follows: Outputs Door lock strike General purpose

Page 26

AC-225 Hardware Settings 1 2 3 4 5 6 7 8 Figure 17: DIP Switch with Internal Network Address Setting Note: For successful communications, t

Page 27

AC-225 Hardware Settings AC-225 Hardware Installation and User Guide Page 32 18 On Off Off Off On 19 On Off Off On Off 20 On Off Off On On 21

Page 28 - 5. AC-225 Hardware Settings

Communications 6. Communications Communication lines are used to upload and download information between the access control panel and the VeriTrax AS

Page 29 - Function

Communications RS-232 Connection to the Computer Set the J1 switch to the RS-232 position. Access control panel DB9 Connector DB25 Connector GND Pin

Page 30

Communications Daisy Chaining Daisy chaining allows many panels to connect to the computer along a single serial line. The first panel is connected di

Page 31 - Double Door Controller

Communications 6.2 TCP/IP Network Connection The computer running the VeriTrax AS-225 software can communicate with the access control panels via a T

Page 32

Communications RS-232 MD-N32 Access Control Panel LAN/WAN Figure 19: MD-N32 Configuration connecting a single panel When using an MD-N32, for a singl

Page 33

Communications 6.3 Modem Network Connection Access control panels can be controlled from the computer's modem. The modem is assigned from within

Page 34 - 6. Communications

Introduction AC-225 Hardware Installation and User Guide Page 3 1. Introduction AC-225, AC-225IP and AC-225U access control panels are state-of-the-

Page 35

Communications Prerequisites Before performing permanent modem installations, the modem that will be connected to the panel must be initialized from

Page 36 - Daisy Chaining

Limited Warranty AC-225 Hardware Installation and User Guide Page 40 Appendix A. Limited Warranty ROSSLARE ENTERPRISES LIMITED S (Rosslare) TWO YE

Page 37 - LAN and WAN Requirements

Limited Warranty AC-225 Hardware Installation and User Guide Page 41 Exclusions and Limitations ROSSLARE shall not be responsible or liable for any

Page 38

Technical Support AC-225 Hardware Installation and User Guide Page 42 Appendix B. Technical Support Asia Pacific, Middle East, Africa Rosslare Secu

Page 40 - AC-225 Panel Connections

0706-0960202+00 www.rosslaresecurity.com

Page 41 - Warranty Remedy Coverage

Introduction Figure 1 AC-225 panel AC-225 Hardware Installation and User Guide Page 4

Page 42 - Limited Warranty Terms

Introduction 1.1 Features The AC-225 is a powerful and adaptable access control solution with a range of powerful features. • Controls 1 or 2 doors

Page 43

Introduction AC-225 Hardware Installation and User Guide Page 6 Client-Server Structure VeriTrax AS-225 operates through a dedicated VeriTrax server

Page 44

Technical Specifications AC-225 Hardware Installation and User Guide Page 7 2. Technical Specifications Electrical Characteristics Operating Voltage

Page 45 - 0706-0960202+00

Technical Specifications AC-225 Hardware Installation and User Guide Page 8 Communication Characteristics RS-232 Terminal Block RS-485 Molex and T

Comments to this Manuals

No comments